Condor Spill Containment System
The Condor System, used in wet-cell battery applications, is a non liner-based spill containment system that complies with NFPA, International Fire Code (IFC), and OSHA. It has metal barrier walls with an acid-resistant, safety yellow coating. Flanges may be in or out to save floor space.
The CondorPlus, used in wet-cell battery applications, is a UL Listed, liner based, spill containment system that complies with NFPA, International Fire Code (IFC), Underwriters Laboratories (UL), and OSHA. It has a Class 1 fire rated, corrosive resistant, pre-formed liner and metal barrier walls with acid-resistant, safety yellow coating. Flanges must be out for fitment of the liner.
CondorCondorPlusVideosFIT Training
Features
- Utilizes epoxy floor coating
- Acid-Resistant coating (Safety Yellow)
- Modular design for future expansion
- Can be configured to fit most applications
- Space-saving design maximizes aisle width
- Optional Liner with Class 1 fire rating (CondorPlus)
Part Number
- EGS-WW-LLL (i.e. EGS PLUS 30-120)
- WW = Width in Inches
- LLL = Length in Inches
Regulations In Compliance With
- NFPA
- International Fire Code (IFC)
- OSHA
Specifications
- 4" Coated, 16 Gauge Steel Barriers with 2" Flanges
- System includes 12"x12" Neutralization and Absorption Pillows (NABPILs) and 4"x24" Neutralization and Absorption Pillows (SOCs)
- KOH NABPILs and SOC's substituted for NiCd Battery Applications
 
View Patents
CONDOR PLUS™ SYSTEM
Liner-Based for Flooded & NiCd Battery Applications
Features
- Corrosive-resistant liner with Class 1 fire rating (NFPA 101)
- Acid-resistant coating (Safety Yellow)
- High-strength steel barriers
- Corrosive-resistant liner ensures reliable spill protection
- Modular design for minor on-site adjustments and future expansion
- UL Listed
- FM Approved pillows available
Part Number
- EGS-PLUS-WW-LLL (i.e. EGS PLUS 30-120)
- WW = Width in Inches
- LLL = Length in Inches
Regulations In Compliance With
- NFPA
- International Fire Code (IFC)
- Underwriters Laboratories (UL)
- OSHA
Specifications
- 4" Coated, 16 Gauge Steel Barriers with 2" Flanges
- Standard 60 mil Polymeric Liner
- Optional 80 mil Polymeric Liner
- System includes 12"x12" Neutralization and Absorption Pillows (NABPILs) and 4"x24" Neutralization and Absorption Pillows (SOCs)
- KOH NABPILs and SOC's substituted for NiCd Battery Applications
 
View Patents
Factory Installer Training
EnviroGuard's UL Listed Spill Containment systems utilize a preformed liner, modular barriers and fire-resistant acid neutralization and absorption pillows. This course presents a proven process for installing the spill containment systems to ensure system is liquid-tight and installed per Underwriters Laboratories accepted procedure. Installation technicians will be able to confidently install EnviroGuard's spill containment systems for flooded, VRLA, battery cabinet and relay rack applications.
Learn more about this and our other available training courses
|